Portable generator

Portable generator

GE 20 PSX Open · Petrol

Robust open-frame portable petrol generator with PERKINS - 404A-22G1, 22 kVA / 16 kW, 3-phase, 400/230 V.

LTP
22 kVA
PRP
20 kVA
Voltage
3-phase
Fuel
Petrol
GE 20 PSX22 kVA / 17.6 kW (LTP) • 3-phase • Petrol
PERKINS petrol engine
max. 22 kVA
3-phase
CE-compliant
Electric start

Classification

Applications of the portable generator

This model is suitable for temporary power supply on construction sites, during service work, at events and for mobile applications. Power, fuel and voltage are summarized for technical selection.

Power & voltage20 kVA (PRP) / 22 kVA (LTP) for 400/230 V 3-phase output.
Engine & fuelPERKINS - 404A-22G1 with petrol operation, water-cooled.
Tank & handlingTank 60 lt.; runtime at 75% PRP 21.5 h; dry weight 650 kg; protection degree IP 23; dimensions 1720 x 985 x 1128 mm.

Technical data

Technical data at a glance

GE 20 PSX

Features

  • Automatic voltage regulation “AVR” with three-phase sensing
  • Engine cowling side, can be completely opened, which facilitates all maintenance operations
  • The recessed control panel is lockable and houses the sockets and machine controls
  • Central lifting eye
  • Ready for connection to automatic transfer unit EAS (AMF + ATS)
  • Meets EC directives for noise and safety
Power kVA 20 kVA (PRP)22 kVA (LTP)
Power kW 16 kW (PRP)17.6 kW (LTP)
Voltage (3-phase) 400/230 V
Cooling system Water-cooled
Fuel Petrol

Engine and generator data

EnginePERKINS - 404A-22G1
CoolingWater-cooled
Cylinders4
Displacement2216 cm³
Speed governorMechanical
Oil sump capacity/
Fuel consumption 110%6.1 lt./h
Fuel consumption 100% PRP5.3 lt./h
Fuel consumption 75% PRP4 lt./h
Fuel consumption 50% PRP2.9 lt./h
Generator data
Main featuresSYNCHRONOUSOUS, THREE-PHASE, SELF-EXCITED, SELF-REGULATED, BRUSHLESS
AVR modelHVR-30 (3ph. sensing)
Voltage regulation precision± 1 %

General data

Voltage400/230 V
Phase3-phase
Protection degreeIP 23
Tank capacity60 lt.
Runtime at 75% PRP21.5 h
Starter battery12 Vdc -80Ah
Dimensions (L x W x H)1720 x 985 x 1128 mm
Dry weight of machine650 Kg
Measured sound power level Lwa (pressure LpA) *90 dB(A) (65 dB(A) @ 7 m)
Guaranteed sound power level Lwa (pressure LpA) *91 dB(A) (66 dB(A) @ 7 m)

* Betrieb in Räumen unter Berücksichtigung der Richtlinie 2000/14/EC

Control panel

  • Controller EP6
  • Fuel level gauge
  • Siren
  • Emergency stop button
  • Local-Remote Start switch
  • EAS plug
  • TCM 35 remote control plug
  • Voltmeter switch 0 - RS - ST - TR
  • Four pole circuit breaker
  • ELCB-GFI (Ground Fault Interruptor)
  • Output sockets 1x400V 32A 3P+N+T CEE1x400V 16A 3P+N+T CEE2x230V 16A 2P+T CEE
  • Circuit breaker for 400V 16A socket

Definitions:

Ambient conditions for power ratings: Temperature 25°C, altitude 1000 m above sea level, relative humidity 30%.

Standby power (LTP): Emergency power. Maximum available power for operation with variable loads, limited to 500 hours per year. Overload is not permitted.

Prime Power (PRP): Prime power with variable loads. Maximum available power for operation with variable loads for an unlimited number of hours per year. The average power during a 24-hour period must not exceed 70% of the stated value.

Continuous power (COP): Continuous power with constant load. Maximum available power for operation with constant load for an unlimited number of hours per year.

Note: The data is taken from the original technical datasheet. Displayed values are nominal values, may change without prior notice and may vary by up to ±5%.

Inquiry

Prepare inquiry

The selected model is already included. Add your requirements regarding price, delivery time or technical specifications.

  • Model and core data are added automatically.
  • Price, availability and delivery time can be requested directly.
  • Technical requirements can be added in the message field.
Inquiry for:Portable generatorModel and key data are included

Download & comparison

Open datasheet or compare further portable generators

Verified technical answer

GE 20 PSX at a glance

GE 20 PSX is a three-phase benzin portable generator with 20 kVA / 16 kW PRP and 22 kVA / 17.6 kW LTP. The values below are taken from the assigned, field-audited manufacturer datasheet.

PRP output20 kVA / 16 kW
LTP output22 kVA / 17.6 kW
Phase / voltage3-phase / 400/230 V
FuelBenzin
EnginePERKINS - 404A-22G1
Tank / runtime60 lt. / 21.5 h

How should the output be interpreted?

PRP and LTP describe different rated operating conditions. The connected loads, starting currents and operating duration still need to be checked.

What confirms these values?

The visible values and structured data use the same field-audited manufacturer datasheet.