Robust open-frame portable petrol generator with HONDA iGX 800, 17 kVA / 13.6 kW, 3-phase, 400/230 V.

LTP
17 kVA
PRP
15 kVA
Voltage
3-phase
Fuel
Petrol
GE 17054 HBT17 kVA / 13.6 kW (LTP) • 3-phase • Petrol
HONDA petrol engine
max. 17 kVA
3-phase
CE-compliant
Electric start

Classification

Applications of the portable generator

This model is suitable for temporary power supply on construction sites, during service work, at events and for mobile applications. Power, fuel and voltage are summarized for technical selection.

Power & voltage15 kVA (PRP) / 17 kVA (LTP) for 400/230 V 3-phase output.
Engine & fuelHONDA iGX 800 with petrol operation, air-cooled.
Tank & handlingTank 18 lt.; runtime at 75% PRP 3.8 h; dry weight 175 kg; protection degree IP 54; dimensions 935 x 525 x 645 mm.

Technical data

Technical data at a glance

GE 17054 HBT

Features

  • Honda iGX engine with electronic speed control
  • Electronic injection
  • Automatic Starter (Auto- Choke)
  • Auto-Idle function as standard
  • Electronic voltage regulation “AVR”
  • Brushless
  • Isolation monitor
  • Switch magnetermic
  • Differential switches
  • Compliant with German Regulation DGVU-I 203-032
  • Compliant with CE directives
Power kVA 15 kVA (PRP)17 kVA (LTP)
Power kW 12 kW (PRP)13.6 kW (LTP)
Voltage (3-phase) 400/230 V
Cooling system Air cooled
Fuel Petrol

Engine and generator data

EngineHONDA iGX 800
CoolingAir cooled
Cylinders2 a V
Displacement779 cm³ (0.779 lt.)
Speed governorElectronic
Oil sump capacity2 lt.
Fuel consumption 110%6.9 lt./h
Fuel consumption 100% PRP6.3 lt./h
Fuel consumption 75% PRP4.7 lt./h
Fuel consumption 50% PRP3.2 lt./h
Generator data
Main featuresSYNCHRONOUSOUS, THREE-PHASE, SELF-EXCITED, SELF-REGULATED
AVR modelAnalogico
Voltage regulation precision± 1 %

General data

Voltage400/230 V
Phase3-phase
Protection degreeIP 54
Tank capacity18 lt.
Runtime at 75% PRP3.8 h
Starter battery12 Vdc -37Ah / 330A CCA(EN)
Dimensions (L x W x H)935 x 525 x 645 mm
Dry weight of machine175 Kg
Sound power level Lwa (pressure LpA) *99 dB(A) (74 dB(A) @ 7 m)

* Betrieb in Räumen unter Berücksichtigung der Richtlinie 2000/14/EC

Control panel

  • Starter key
  • Oil alert warning light (led)
  • Hour meter
  • Fuel tap
  • Auto-Idle switch
  • voltmeter
  • General magnetothermic switch
  • Isolation monitor
  • Differential-magneto-thermal switch for 230V 16A sockets
  • Output sockets 1x400V 32A 3P + N + T CEE IP672x230V 16A 2P + T Schuko
  • Earth terminal (PE)

Definitions:

Ambient conditions for power ratings: Temperature 25°C, altitude 1000 m above sea level, relative humidity 30%.

Standby power (LTP): Emergency power. Maximum available power for operation with variable loads, limited to 500 hours per year. Overload is not permitted.

Prime Power (PRP): Prime power with variable loads. Maximum available power for operation with variable loads for an unlimited number of hours per year. The average power during a 24-hour period must not exceed 70% of the stated value.

Continuous power (COP): Continuous power with constant load. Maximum available power for operation with constant load for an unlimited number of hours per year.

Note: The data is taken from the original technical datasheet. Displayed values are nominal values, may change without prior notice and may vary by up to ±5%.

Inquiry

Prepare inquiry

The selected model is already included. Add your requirements regarding price, delivery time or technical specifications.

  • Model and core data are added automatically.
  • Price, availability and delivery time can be requested directly.
  • Technical requirements can be added in the message field.
Inquiry for:Portable generatorModel and key data are included

Download & comparison

Open datasheet or compare further portable generators

Verified technical answer

GE 17054 HBT at a glance

GE 17054 HBT is a three-phase benzin portable generator with 15 kVA / 12 kW PRP and 17 kVA / 13.6 kW LTP. The values below are taken from the assigned, field-audited manufacturer datasheet.

PRP output15 kVA / 12 kW
LTP output17 kVA / 13.6 kW
Phase / voltage3-phase / 400/230 V
FuelBenzin
EngineHONDA iGX 800
Tank / runtime18 lt. / 3.8 h

How should the output be interpreted?