Portable generator
GE 10 YSX Super silenced · Diesel
Super silenced portable diesel generator with YANMAR 3TNV80, 9.5 kVA / 8 kW, 3-phase, 400/230 V.
- LTP
- 9.5 kVA
- PRP
- 9 kVA
- Voltage
- 3-phase
- Fuel
- Diesel
Classification
Applications of the portable generator
This model is suitable for temporary power supply on construction sites, during service work, at events and for mobile applications. Power, fuel and voltage are summarized for technical selection.
Technical data
Technical data at a glance

Features
- Combined system voltage regulation: electronic AVR + Compound
- The rounded edges of the canopy designed for rainwater drainage away
- Bunded base suitable to contain any liquids leakage from engine avoiding environmental pollution
- External caps for oil and water drain
- Large doors for better and easy maintenance (air, oil, fuel filters replacement)
- Central lifting eye
- Forklift pockets
- Ready for connection to automatic transfer unit EAS (AMF + ATS)
- Meets EC directives for noise and safety
Engine and generator data
General data
* Betrieb in Räumen unter Berücksichtigung der Richtlinie 2000/14/EC
Control panel
- Controller EP6
- Fuel level gauge
- Siren
- Emergency stop button
- Local-Remote Start switch
- EAS plug
- TCM 35 remote control plug
- Voltmeter switch 0 - RS - ST - TR
- Circuit breaker
- ELCB-GFI (Ground Fault Interruptor)
- Output sockets 1x400V 16A 3P+N+TCEE2x230V 16A 2P+T CEE1x400V 16A 3P+N+TCEE2x230V 16A 2P+T SCHUKO
- Earth terminal (PE)
Definitions:
Ambient conditions for power ratings: Temperature 25°C, altitude 1000 m above sea level, relative humidity 30%.
Standby power (LTP): Emergency power. Maximum available power for operation with variable loads, limited to 500 hours per year. Overload is not permitted.
Prime Power (PRP): Prime power with variable loads. Maximum available power for operation with variable loads for an unlimited number of hours per year. The average power during a 24-hour period must not exceed 70% of the stated value.
Continuous power (COP): Continuous power with constant load. Maximum available power for operation with constant load for an unlimited number of hours per year.
Note: The data is taken from the original technical datasheet. Displayed values are nominal values, may change without prior notice and may vary by up to ±5%.
Inquiry
Prepare inquiry
The selected model is already included. Add your requirements regarding price, delivery time or technical specifications.
- Model and core data are added automatically.
- Price, availability and delivery time can be requested directly.
- Technical requirements can be added in the message field.
Download & comparison
Open datasheet or compare further portable generators
Verified technical answer
GE 10 YSX at a glance
GE 10 YSX is a three-phase diesel portable generator with 9 kVA / 7.2 kW PRP and 9.5 kVA / 7.6 kW LTP. The values below are taken from the assigned, field-audited manufacturer datasheet.
| PRP output | 9 kVA / 7.2 kW |
|---|---|
| LTP output | 9.5 kVA / 7.6 kW |
| Phase / voltage | 3-phase / 400/230 V |
| Fuel | Diesel |
| Engine | YANMAR 3TNV80 |
| Tank / runtime | 55 lt. / 27.5 h |
How should the output be interpreted?
PRP and LTP describe different rated operating conditions. The connected loads, starting currents and operating duration still need to be checked.
What confirms these values?
The visible values and structured data use the same field-audited manufacturer datasheet.