Portable generator
GE S-7000 HBM Protective frame · Petrol
Portable petrol generator with protective frame and HONDA GX 390 HONDA iGX 390, 7.2 kVA / 5.6 kW, 1-phase, 230 V.
- LTP
- 7.2 kVA
- PRP
- 6 kVA
- Voltage
- 1-phase
- Fuel
- Petrol
Classification
Applications of the portable generator
This model is suitable for temporary power supply on construction sites, during service work, at events and for mobile applications. Power, fuel and voltage are summarized for technical selection.
Technical data
Technical data at a glance

Features
- Electric starter with electronic rpm regulation (iGX Vers.)
- Engine shut down for low oil level
- Sockets: 1x230V 32A 2P+T CEE 1x230V 16A 2P+T CEE 1x230V 16A 2P+T Schuko
- Circuit breaker
- Fuel level gauge
- Protective frame and partially covered
- Portable
- Meets EC directives for noise and safety
- AVR version on request (standard for the iGX vers.)
- Ready for connection to automatic transfer unit EAS (iGX Vers.)
- Automatic Starter (Auto Choke) (Vers. IGX)
Engine and generator data
General data
* Betrieb in Räumen unter Berücksichtigung der Richtlinie 2000/14/EC
Control panel
- Engine start and stop key (Vers. IGX)
- Motor switch ON - OFF (AA)
- Air control
- Fuel tap
- Fuel level indicator
- Multifunction digital instrument: Voltmeter - Frequency meter - Total hour meter - Partial hour meter (resettable)
- Circuit breaker
- ELCB-GFI (Ground Fault Interruptor)
- Output sockets 1x230V 32A 2P + T CEE1x115V 32A 2P + T CEE1x115V 16A 2P + T CEE
- Thermal breakers for socket protection: 1x30A - 1x16A
- Voltage switch: 230 / 115V
- Earth terminal (PE)
Definitions:
Ambient conditions for power ratings: Temperature 25°C, altitude 1000 m above sea level, relative humidity 30%.
Standby power (LTP): Emergency power. Maximum available power for operation with variable loads, limited to 500 hours per year. Overload is not permitted.
Prime Power (PRP): Prime power with variable loads. Maximum available power for operation with variable loads for an unlimited number of hours per year. The average power during a 24-hour period must not exceed 70% of the stated value.
Continuous power (COP): Continuous power with constant load. Maximum available power for operation with constant load for an unlimited number of hours per year.
Note: The data is taken from the original technical datasheet. Displayed values are nominal values, may change without prior notice and may vary by up to ±5%.
Inquiry
Prepare inquiry
The selected model is already included. Add your requirements regarding price, delivery time or technical specifications.
- Model and core data are added automatically.
- Price, availability and delivery time can be requested directly.
- Technical requirements can be added in the message field.
Download & comparison
Open datasheet or compare further portable generators
Verified technical answer
GE S-7000 HBM at a glance
GE S-7000 HBM is a single-phase benzin portable generator with 6 kVA / 5.4 kW PRP and 7.2 kVA / 6.5 kW LTP. The values below are taken from the assigned, field-audited manufacturer datasheet.
| PRP output | 6 kVA / 5.4 kW |
|---|---|
| LTP output | 7.2 kVA / 6.5 kW |
| Phase / voltage | 1-phase / 230 V |
| Fuel | Benzin |
| Engine | HONDA GX 390 HONDA iGX 390 |
| Tank / runtime | 20 lt. / 8.5 h |
How should the output be interpreted?
PRP and LTP describe different rated operating conditions. The connected loads, starting currents and operating duration still need to be checked.
What confirms these values?