Portable generator
GE S-6000 YDM Protective frame · Diesel
Portable diesel generator with protective frame and YANMAR L100N, 5.7 kVA / 4.8 kW, 1-phase, 230 V.
- LTP
- 5.7 kVA
- PRP
- 5 kVA
- Voltage
- 1-phase
- Fuel
- Diesel
Classification
Applications of the portable generator
This model is suitable for temporary power supply on construction sites, during service work, at events and for mobile applications. Power, fuel and voltage are summarized for technical selection.
Technical data
Technical data at a glance

Features
- Manual recoil (AA)
- Low oil pressure automatic engine shut down (AE)
- Sockets: 1x 230V 32A 2P+T CEE 1x 230V 16A 2P+T CEE 1x 230V 16A 2P+T Schuko
- Circuit breaker
- Fuel level gauge
- Protective frame and partially covered
- Ready for connection to automatic transfer unit EAS (AE)
- Meets EC directives for the safety
Engine and generator data
General data
* Indoor operation in accordance with Directive 2000/14/EC.
Control panel
- Start and stop engine key (AE)
- Low oil pressure shutdown light (AE)
- Battery charge warning light fault (AE)
- Local-Remote Start switch (AE)
- EAS plug (AE)
- Digital multifunction meter: Voltmeter - Frequencymeter -Total Hoursmeter - Partial Hoursmeter (resettable)
- Fuel gauge
- Fuel valve
- Circuit breaker
- Output sockets 1x 230V 32A 2P+T CEE1x 230V 16A 2P+T CEE1x 230V 16A 2P+T Schuko
- Earth terminal (PE)
Definitions:
Ambient conditions for power ratings: Temperature 25°C, altitude 1000 m above sea level, relative humidity 30%.
Standby power (LTP): Emergency power. Maximum available power for operation with variable loads, limited to 500 hours per year. Overload is not permitted.
Prime Power (PRP): Prime power with variable loads. Maximum available power for operation with variable loads for an unlimited number of hours per year. The average power during a 24-hour period must not exceed 70% of the stated value.
Continuous power (COP): Continuous power with constant load. Maximum available power for operation with constant load for an unlimited number of hours per year.
Note: The data is taken from the original technical datasheet. Displayed values are nominal values, may change without prior notice and may vary by up to ±5%.
Inquiry
Prepare inquiry
The selected model is already included. Add your requirements regarding price, delivery time or technical specifications.
- Model and core data are added automatically.
- Price, availability and delivery time can be requested directly.
- Technical requirements can be added in the message field.
Download & comparison
Open datasheet or compare further portable generators
Verified technical answer
GE S-6000 YDM at a glance
GE S-6000 YDM is a single-phase diesel portable generator with 5 kVA / 4.5 kW PRP and 5.7 kVA / 5.1 kW LTP. The values below are taken from the assigned, field-audited manufacturer datasheet.
| PRP output | 5 kVA / 4.5 kW |
|---|---|
| LTP output | 5.7 kVA / 5.1 kW |
| Phase / voltage | 1-phase / 230 V |
| Fuel | Diesel |
| Engine | YANMAR L100V |
| Tank / runtime | 20 lt. / 20 h |
How should the output be interpreted?
PRP and LTP describe different rated operating conditions. The connected loads, starting currents and operating duration still need to be checked.
What confirms these values?
The visible values and structured data use the same field-audited manufacturer datasheet.