Portable generator

Portable generator

GE S-5000 HBM Protective frame · Petrol

Portable petrol generator with protective frame and HONDA GX 270 HONDA iGX 270, 4.9 kVA / 4 kW, 1-phase, 230 V.

LTP
4.9 kVA
PRP
4 kVA
Voltage
1-phase
Fuel
Petrol
GE S-5000 HBM4.9 kVA / 4.4 kW (LTP) • 1-phase • Petrol
HONDA petrol engine
max. 4.9 kVA
1-phase
CE-compliant
Electric start

Classification

Applications of the portable generator

This model is suitable for temporary power supply on construction sites, during service work, at events and for mobile applications. Power, fuel and voltage are summarized for technical selection.

Power & voltage4 kVA (PRP) / 4.9 kVA (LTP) for 230 V 1-phase output.
Engine & fuelHONDA GX 270 HONDA iGX 270 with petrol operation, air-cooled.
Tank & handlingTank 20 lt.; runtime at 75% PRP 12.5 h; dry weight 76 kg; protection degree IP 23; dimensions 770 x 520 x 650 mm.

Technical data

Technical data at a glance

GE S-5000 HBM

Features

  • Electric Starter with electronic voltage regulation (Vers. iGX)
  • Engine shut down for low oil level (oil alert)
  • Sockets: 1x230V 32A 2P+T CEE 1x230V 16A 2P+T CEE 1x230V 16A 2P+T Schuko
  • Circuit breaker
  • Fuel level gauge
  • Protective frame and partially covered
  • Portable
  • Meets EC directives for noise and safety
  • AVR version on request (standard for iGX version)
  • Ready for connection to automatic transfer unit EAS (Vers. iGX)
  • Automatischer Starter (Auto Choke) (Vers. iGX)
Power kVA 4 kVA (PRP)4.9 kVA (LTP)
Power kW 3.6 kW (PRP)4.4 kW (LTP)
Voltage (1-phase) 230 V
Cooling system Air cooled
Fuel Petrol

Engine and generator data

EngineHONDA GX 270 HONDA iGX 270
CoolingAir cooled
Cylinders5.7 kWm (7.7 hp)
DisplacementOn request
Speed governorMechanical Electronic
Oil sump capacity1.1 lt.
Fuel consumption 110%2.4 lt./h
Fuel consumption 100% PRP2.1 lt./h
Fuel consumption 75% PRP1.6 lt./h
Fuel consumption 50% PRP1.1 lt./h
Generator data
Main featuresSYNCHRONOUSOUS, SINGLE-PHASE, SELF-EXCITED, SELF-REGULATED, BRUSHLESS (WITHOUT AVR)
AVR modelHVR10E
Voltage regulation precision± 1 %

General data

Voltage230 V
Phase1-phase
Protection degreeIP 23
Tank capacity20 lt.
Runtime at 75% PRP12.5 h
Starter battery/
Dimensions (L x W x H)770 x 520 x 650 mm
Dry weight of machine76 Kg
Measured sound power level Lwa (pressure LpA) *95 dB(A) (70 dB(A) @ 7 m)
Guaranteed sound power level Lwa (pressure LpA) *96 dB(A) (71 dB(A) @ 7 m)

* Betrieb in Räumen unter Berücksichtigung der Richtlinie 2000/14/EC

Control panel

  • Motor switch ON - OFF (AA)
  • Air control
  • Fuel tap
  • Fuel level indicator
  • Multifunction digital instrument: Voltmeter - Frequency meter - Total hour meter - Partial hour meter (resettable)
  • Switch magnetermic
  • Circuit breaker
  • Output sockets 1x230V 32A 2P + T CEE1x115V 32A 2P + T CEE1x115V 16A 2P + T CEE
  • Thermal breakers for socket protection: 1x30A - 1x16A
  • Voltage switch: 230 / 115V
  • Earth terminal (PE)

Definitions:

Ambient conditions for power ratings: Temperature 25°C, altitude 1000 m above sea level, relative humidity 30%.

Standby power (LTP): Emergency power. Maximum available power for operation with variable loads, limited to 500 hours per year. Overload is not permitted.

Prime Power (PRP): Prime power with variable loads. Maximum available power for operation with variable loads for an unlimited number of hours per year. The average power during a 24-hour period must not exceed 70% of the stated value.

Continuous power (COP): Continuous power with constant load. Maximum available power for operation with constant load for an unlimited number of hours per year.

Note: The data is taken from the original technical datasheet. Displayed values are nominal values, may change without prior notice and may vary by up to ±5%.

Inquiry

Prepare inquiry

The selected model is already included. Add your requirements regarding price, delivery time or technical specifications.

  • Model and core data are added automatically.
  • Price, availability and delivery time can be requested directly.
  • Technical requirements can be added in the message field.
Inquiry for:Portable generatorModel and key data are included

Download & comparison

Open datasheet or compare further portable generators

Verified technical answer

GE S-5000 HBM at a glance

GE S-5000 HBM is a single-phase benzin portable generator with 4 kVA / 3.6 kW PRP and 4.9 kVA / 4.4 kW LTP. The values below are taken from the assigned, field-audited manufacturer datasheet.

PRP output4 kVA / 3.6 kW
LTP output4.9 kVA / 4.4 kW
Phase / voltage1-phase / 230 V
FuelBenzin
EngineHONDA GX 270 HONDA iGX 270
Tank / runtime20 lt. / 12.5 h

How should the output be interpreted?

PRP and LTP describe different rated operating conditions. The connected loads, starting currents and operating duration still need to be checked.

What confirms these values?

The visible values and structured data use the same field-audited manufacturer datasheet.

Technical data reviewed on 20 August 2026 by GGG German Generator GmbH – Technical Project Consulting.Open verified datasheet