Portable generator

Portable generator

GE 10000 HZDM Open · Diesel

Robust open-frame portable diesel generator with HATZ - 1D90, 10 kVA / 8 kW, 1-phase, 230 V.

LTP
10 kVA
PRP
9 kVA
Voltage
1-phase
Fuel
Diesel
GE 10000 HZDM10 kVA / 9 kW (LTP) • 1-phase • Diesel
HATZ diesel engine
max. 10 kVA
1-phase
CE-compliant
Electric start

Classification

Applications of the portable generator

This model is suitable for temporary power supply on construction sites, during service work, at events and for mobile applications. Power, fuel and voltage are summarized for technical selection.

Power & voltage9 kVA (PRP) / 10 kVA (LTP) for 230 V 1-phase output.
Engine & fuelHATZ - 1D90 with diesel operation, air-cooled.
Tank & handlingTank 10 lt.; runtime at 75% PRP 4 h; dry weight 215 kg; protection degree IP 23; dimensions 1005 x 610 x 715 mm.

Technical data

Technical data at a glance

GE 10000 HZDM

Features

  • Low oil pressure automatic engine shut down and high temperature
  • A recessed panel protects the sockets
  • Protective frame
  • Automatic voltage regulation “AVR”
  • Circuit breaker
  • ELCB-GFI (Ground Fault Interruptor)
  • Meets EC directives
Power kVA 9 kVA (PRP)10 kVA (LTP)
Power kW 8.1 kW (PRP)9 kW (LTP)
Voltage (1-phase) 230 V
Cooling system Air cooled
Fuel Diesel

Engine and generator data

EngineHATZ - 1D90
CoolingAir cooled
Cylinders1
Displacement722 cm³ (0.722 lt.)
Speed governorMechanical
Oil sump capacity1.9 lt.
Fuel consumption 110%3.6 lt./h
Fuel consumption 100% PRP3.3 lt./h
Fuel consumption 75% PRP2.5 lt./h
Fuel consumption 50% PRP1.6 lt./h
Generator data
Main featuresSYNCHRONOUSOUS, THREE-PHASE, SELF-EXCITED, SELF-REGULATED, BRUSHLESS
AVR modelHVR 11E
Voltage regulation precision± 1 %

General data

Voltage230 V
Phase1-phase
Protection degreeIP 23
Tank capacity10 lt.
Runtime at 75% PRP4 h
Starter battery12 Vdc -37Ah / 330A CCA(EN)
Dimensions (L x W x H)1005 x 610 x 715 mm
Dry weight of machine215 Kg
Sound power level Lwa (pressure LpA) *105 dB(A) (80 dB(A) @ 7 m)

* Indoor operation in accordance with Directive 2000/14/EC.

Control panel

  • Start and stop engine key
  • Low oil pressure warning light with shutdown
  • High engine temp. shutdown
  • Battery charge warning light fault
  • Digital multifunction meter: Voltmeter - Frequencymeter - Total Hoursmeter - Partial Hoursmeter (resettable)
  • Circuit breaker
  • ELCB-GFI (Ground Fault Interruptor)
  • Thermal circuit breakers for 230V / 16A
  • CEE output sockets 1x 230V 32A 2P+T CEE1x 230V 16A 2P+T CEE1x 230V 16A 2P+T Schuko
  • Earth terminal (PE)

Definitions:

Ambient conditions for power ratings: Temperature 25°C, altitude 1000 m above sea level, relative humidity 30%.

Standby power (LTP): Emergency power. Maximum available power for operation with variable loads, limited to 500 hours per year. Overload is not permitted.

Prime Power (PRP): Prime power with variable loads. Maximum available power for operation with variable loads for an unlimited number of hours per year. The average power during a 24-hour period must not exceed 70% of the stated value.

Continuous power (COP): Continuous power with constant load. Maximum available power for operation with constant load for an unlimited number of hours per year.

Note: The data is taken from the original technical datasheet. Displayed values are nominal values, may change without prior notice and may vary by up to ±5%.

Inquiry

Prepare inquiry

The selected model is already included. Add your requirements regarding price, delivery time or technical specifications.

  • Model and core data are added automatically.
  • Price, availability and delivery time can be requested directly.
  • Technical requirements can be added in the message field.
Inquiry for:Portable generatorModel and key data are included

Download & comparison

Open datasheet or compare further portable generators

Verified technical answer

GE 10000 HZDM at a glance

GE 10000 HZDM is a single-phase diesel portable generator with 9 kVA / 8.1 kW PRP and 10 kVA / 9 kW LTP. The values below are taken from the assigned, field-audited manufacturer datasheet.

PRP output9 kVA / 8.1 kW
LTP output10 kVA / 9 kW
Phase / voltage1-phase / 230 V
FuelDiesel
EngineHATZ - 1D90
Tank / runtime10 lt. / 4 h

How should the output be interpreted?

PRP and LTP describe different rated operating conditions. The connected loads, starting currents and operating duration still need to be checked.

What confirms these values?

The visible values and structured data use the same field-audited manufacturer datasheet.

Technical data reviewed on 20 August 2026 by GGG German Generator GmbH – Technical Project Consulting.Open verified datasheet